www.kineqt.com

ÀÛ¾÷ȯ°æÃøÁ¤Àåºñ

¼ÒÀ½ÃøÁ¤Àåºñ

  QUEST 3M ¼ÒÀ½ÃøÁ¤±â

  SE-401/402

  SoundPro

  SP-OMS

  2100/2200/1100/1200

  È¯°æ¼ÒÀ½ÃøÁ¤±â

  ±â°è¹×¼³ºñÁø´Ü¼ÒÀ½ÃøÁ¤±â

  °ÇÃàÀ½ÇâÃøÁ¤±â

  ±âŸ ¼ÒÀ½ÃøÁ¤±â ÁÖº¯±â±â

Áøµ¿ÃøÁ¤Àåºñ

´ë±âÃøÁ¤Àåºñ

¼öÁúÃøÁ¤Àåºñ

 

 

 ¼ÒÀ½ÃøÁ¤Àåºñ > QUEST 3M ¼ÒÀ½ÃøÁ¤±â > ÀûºÐÇü¼ÒÀ½ÃøÁ¤±â ¹× ÁÖÆļöºÐ¼®±â SoundPro


 ÀûºÐÇü ¼ÒÀ½ÃøÁ¤±â ¹× ÁÖÆļöºÐ¼®±â (Model/SoundPro)

 

                         ÀûºÐÇü ¼ÒÀ½ÃøÁ¤±â ¹× ÁÖÆļöºÐ¼®±â  SoundPro     


  Á¦Ç°Æ¯Â¡

¡Ü SoundPro¢â SE/DL ½Ã¸®Áî´Â Á¤¹ÐÇÑ ¼ÒÀ½¼öÁØÃøÁ¤°ú ±¤¹üÀ§ÇÑ µ¥ÀÌÅͺм®À» Á¦°øÇÕ´Ï´Ù.
¡Ü Class 1 °ú Class 2¸ðµÎ °¡´ÉÇϸç È­¸é    ÀÌ Ä¿¼­ ½Ç½Ã°£ ¼ÒÀ½ºÐ¼®À» Çϱ⿡ ´õ¿í Æí¸®ÇÏ¸ç µ¥ÀÌÅÍÀúÀå½Ã µ¥ÀÌÅÍ ÈÄó¸® ¹× ÀÛ¾÷     ÀåÀÇ ¼ÒÀ½¼öÁØÆò°¡¸¦ ½±°Ô µµ¿ÍÁÝ´Ï´Ù.
¡Ü °ø±â¿ªÇÐÀû µðÀÚÀÎÀ» Àû¿ëÇÏ¿© ÃøÁ¤ÇÏ°íÀÚ ÇÏ´Â À½Àå(Sound Fields)¿¡ ÁÖ´Â ¿µÇâÀ» ÃÖ¼ÒÈ­ ÇÕ´Ï´Ù.
¡Ü »ê¾÷Àå¿¡¼­ ȤÀº û·Âº¸È£¸¦ À§ÇÑ »ùÇøµ ¾÷¹«¸¦ ÇÒ ¶§, SoundPro¢â SE/DL ½Ã¸®Áî´Â Á¤È®¼º, »ç¿ëÀÇ Æí¸®¼º ±×¸®°í Àü¹®ÀûÀÎ ¾÷     ¹«¼öÇàÀ» À§ÇÑ µ¥ÀÌÅ͸¦ Á¦°øÇÕ´Ï´Ù.
¡Ü SoundPro¢â SE/DL ½Ã¸®Áî´Â ³ëÃâ¼ÒÀ½ºÐ¼® ¹× ¼­·ùÀÛ¾÷ÀÌ ¾ÆÁÖ °£´ÜÇÏ°í ½±½À´Ï´Ù.
¡Ü ¼ÒÀ½ÀÇ ±¤´ë¿ªÀ» ÃøÁ¤Çϸ鼭 µ¿½Ã¿¡ 1/1¿ÁŸºê ¿Í 1/3¿ÁŸºê·Î ÃøÁ¤ÇÒ ¼ö ÀÖ½À´Ï´Ù.
¡Ü »ç¿ëÀÚ°¡ Á÷Á¢ ¸Þ´º¸¦ ¼±ÅÃÇÏ¿© »ç¿ëÇÒ ¼ö ÀÖ´Â ±â´ÉÀ¸·Î´Â Å°Æеå Ä̸®ºê·¹À̼Ç, SD ¸Þ¸ð¸®Ä«µå Á¦°Å °¡´É,±×¸®°í QuestSuite¢â     Professional II ¼ÒÇÁÆ®¿þ¾î »ç¿ëÀ» ¼±ÅÃÇÒ ¼ö ÀÖ½À´Ï´Ù.

- SoundPro½Ã¸®Áî´Â Á¤È®ÇÑ ¼ÒÀ½ÃøÁ¤±â·Î û·Âº¸È£ÇÁ·Î±×·¥À» Áö¿øÇص帮°í »ç¾÷Àå¿¡¼­ û·Âº¸È£ ¹ý±Ô¸¦ ÀÌÇàÇϴµ¥µµ µµ¿òÀ» µå   ¸³´Ï´Ù.


  »ç¿ëó

¡Ü »ê¾÷Àå¿¡¼­ ¼ÒÀ½ÃøÁ¤                                                        ¡Ü ÀÚµ¿Â÷ ¼ÒÀ½ Æò°¡
¡Ü ȯ°æ ¼ÒÀ½Æò°¡                                                                 ¡Ü Ç°Áú Á¦¾î ¹× ÇÁ·Î¼¼½º ÃøÁ¤
¡Ü ¹ýÀû ¼ÒÀ½ Á¦ÇÑ ¹× ±ÔÁ¤ ÀÌÇà                                              ¡Ü ºôµù ¼ÒÀ½
¡Ü ÀϹÝÀûÀÎ À½Çâ°ú ÁÖÆļö ºÐ¼®

 

 

 
 

SPL Display

ÁؾƳ¯·Î±× µð½ºÇ÷¹ÀÌ¿Í ¼öÄ¡ Ç¥½Ã
ÃøÁ¤µÇ´Â À½¾Ð¼öÁØ(SPL; Sound Pressure Level)À» ¼³Á¤µÈ time response °ª°ú filter weighting¿¡ µû¶ó º¸¿©ÁÝ´Ï´Ù. ÃøÁ¤°ªÀÇ Å©±â´Â È­¸éÀÇ ¹ÙÀÇ ±æÀÌ¿Í ÇÏ´ÜÀÇ ¼ýÀÚ·Î µ¿½Ã¿¡ º¼ ¼ö ÀÖ½À´Ï´Ù. ¹Ù´Â ÃøÁ¤°¡´ÉÇÑ ÃÖ¼Ò°ª¿¡¼­ºÎÅÍ ³ªÅ¸³³´Ï´Ù.

 

 

1/1 ¿ÁŸºê

´ÙÁß ¹Ù Â÷Æ® µð½ºÇ÷¹ÀÌ
¼³Á¤µÈ ÇÊÅ͹êµå¿¡ µû¶ó 1/1 ¿ÁŸºê ºÐ¼® °á°ú°¡ µ¿½Ã¿¡ µÎ °¡Áö ÇüÅ·Πº¸¿©ÁÝ´Ï´Ù.
È­¸é¿¡´Â 13°³ÀÇ ¹Ù, 11°³ÀÇ ÇÊÅ͹êµå, 2°³ÀÇ ºê·Îµå¹êµå°¡ Ç¥½ÃµË´Ï´Ù. ¹Ù´Â ÃøÁ¤°¡´ÉÇÑ ÃÖ¼Ò°ª¿¡¼­ºÎÅÍ ³ªÅ¸³³´Ï´Ù.

 

 

1/3 ¿ÁŸºê

´ÙÁß ¹Ù Â÷Æ® µð½ºÇ÷¹ÀÌ

¼³Á¤µÈ ÇÊÅ͹êµå¿¡ µû¶ó 1/3 ¿ÁŸºê ºÐ¼® °á°ú°¡ µ¿½Ã¿¡ µÎ °¡Áö ÇüÅ·Πº¸¿©ÁÝ´Ï´Ù.
È­¸é¿¡´Â 35°³ÀÇ ¹Ù, 33°³ÀÇ ÇÊÅ͹êµå, 2°³ÀÇ ºê·Îµå¹êµå°¡ Ç¥½ÃµË´Ï´Ù. ¹Ù´Â ÃøÁ¤°¡´ÉÇÑ ÃÖ¼Ò°ª¿¡¼­ºÎÅÍ ³ªÅ¸³³´Ï´Ù.

 


  SoundPro ¿Á¿ÜÃøÁ¤ ½Ã½ºÅÛ(SP-OMS(SoundPro Outdoor Measuring System))

 


- SoundPro ¿Á¿ÜÃøÁ¤ ½Ã½ºÅÛÀº ¿Á¿ÜÃøÁ¤½Ã ¿ì·ÁµÇ´Â ³¯¾¾,   °¢Á¾ ¿À¿° ¹°Áú, ÃøÁ¤±â±â µµ³­ µîÀÇ »óȲ¿¡ ´ëÇØ ´ëºñÇÒ ¼ö   ÀÖµµ·Ï µµ¿ÍÁÝ´Ï´Ù. ¶ÇÇÑ °í¿ë·® ¹èÅ͸® ä¿ëÀ¸·Î 1ÁÖÀÏ
  µ¿¾È ¿¬¼ÓÀûÀÎ ÃøÁ¤ÀÌ °¡´ÉÇÏ¸ç ¹æ¼ö ÄÉÀ̽º ä¿ëÀ¸·Î ÃøÁ¤   Àåºñ¿Í °¢Á¾ ¾×¼¼¼­¸®¸¦ ¾ÈÀüÇÏ°Ô º¸°üÇÒ ¼ö ÀÖ½À´Ï´Ù.

  ½Ã½ºÅÛÀ» ÀÌ·ç´Â ¸ðµç Á¦Ç°ÀÇ ÀçÁúÀº ½ºÅ×Àθ®½º ½ºÆ¿,
  ABS ¶Ç´Â °í¼º´É Çöó½ºÆ½À¸·Î ±¸¼ºµÇ¾î ÀÖ½À´Ï´Ù.
  ¿ÜºÎÃøÁ¤ ½Ã½ºÅÛ¿¡´Â ÃøÁ¤¿¡ ÇÊ¿äÇÑ ¸ÅÆ®, À©µå½ºÅ©¸°,
  °¢Á¾ ÄÉÀ̺í, ¹èÅ͸®¿Í ¾î´ðÅÍ°¡ ¸ðµÎ Æ÷ÇԵǾî ÀÖÀ¸¸ç,
  ÄÉÀ̽º¿¡´Â Àá±ÝÀåÄ¡¸¦ °¡Áö°í ÀÖ¾î ÃøÁ¤Àåºñ¿Í ¾×¼¼¼­¸®
  ¸¦ ¾ÈÀüÇÏ°Ô º¸°üÇÒ ¼ö ÀÖ½À´Ï´Ù.


  ±âŸ Æ÷ÇÔµÈ ¿É¼Ç

¡Ü 1/1 ¿ÁŸºê ¹êµå ½Ç½Ã°£ ºÐ¼®                                                 ¡Ü GPS data ¿¬µ¿°¡´É (GPS receiver)
¡Ü 1/3 ¿ÁŸºê ¹êµå ½Ç½Ã°£ ºÐ¼®                                                 ¡Ü ¸¶ÀÌÅ©·ÎÆù »çÀÌÁî ¼±Åð¡´É(1/4¡±,1/2¡±,and 1¡±)
¡Ü Acoustic spectral curves ±â´É¼±Åà                                       ¡Ü ÀÜÇâ½Ã°£ºÐ¼®°¡´É(RT-60)
¡Ü Speech intelligibility option


  Á¦Ç°»ç¾ç

»ç¾ç / Á¦Ç°¹øÈ£

SoundPro

GENERAL :

 

DISPLAY LANGUAGES

English, French, Spanish, German, Italian and Portuguese

USER INTERFACE

10 pushbuttons and 4 soft keys, menu driven

DISPLAY TYPE

Transflective 128 X 64 Dot Matrix LCD with additional fiber optic backlighting

STANDARDS:

EN/IEC 61672, ANSI S1.4, ANSI S1.43, EN/IEC 61260, ANSI S1.11, CISPR 16-1, IEC 6100-4-2, IEC 6100-6-2 (also meets requirements of former standards IEC 60651 and 60804)

CE Mark

 

MEASUREMENTS :

 

PARAMETERS

SPL, LMAX, LMIN, Peak, LEQ, LAVG, SEL, LN (selectable L1 to L99), TWA, Taktm, Taktmx, Dose, PDose, Exposure (Pa2H/Pa2S), LDN, CNEL, PTWA, L C-A

RANGES

120 dB+ (A-weighted) total dynamic measurement range over 8 individual ranges of 90 dB (A-weighted) each (with filters - 80 dB ranges); overall measurement range 0 dB to 140 dB

PEAK RANGE

Up to 143 dB using standard BK4936 microphone; higher with optional microphones and preamps

FREQUENCY WEIGHTING

A, C, Z and F (Flat)

RESPONSE TIME

Fast, Slow, IEC Impulse

EXCHANGE RATES

3, 4, 5, and 6 dB

CRITERION LEVEL

40 to 100 dB

UPPER LIMIT TIME LOGGING

10 to 140 dB selectable

RUN MODES

Level triggered run/pause, clock/date triggered power on and run for programmed duration, external logic input run/pause, and keypad initiated run/pause for programmed duration

MEASUREMENT REFERENCES

SPL: 114 dB Frequency: 1 kHz Direction: 0 degrees using free-field response microphone

OCTAVE AND THIRD OCTAVE FILTERS (OPTIONAL):

 

FULL OCTAVE FILTERS

11 bands with center frequencies from 16 Hz to 16 kHz

THIRD OCTAVE FILTERS

33 bands with center frequencies from 12.5 Hz to 20 kHz

CALIBRATION:

 

HISTORY

Complete calibration history with post study verification logged with calibration history

LOGGING AND STORAGE:

 

LOGGING
 

DL Models only. Max, Min, Peak, LN, LEQ / LAVG may be logged at 11 selectable intervals from one second to 60 minutes to the included SD (secure digital) memory card. Use QuestSuite¢â Professional II to interpret data files

SUMMARY DATA
 

All session/study data is stored to the SD card. Summary data may be interpreted with QuestSuite¢â Professional II or exported to spreadsheet or XML file with an available utility

MEMORY
 

Accepts 32 MB to 32 GB SD memory cards. Card included with all models and is required to store multiple Summary sessions/studies and for setup storage Contact factory for preferred SD card manufacturers

SPECIAL FUNCTIONS:

 

BACK ERASE

Selectable 1 second to 20 seconds removal of measurement data (data removed by back erasing retained in session file)

SECURITY

4 digit code protection for Runs and Setups available

OPTIONAL ACOUSTIC
SPECTRAL CURVES
 

Noise Criterion (NC) Curves, Preferred Noise Criterion (PNC) Curves, Room Criterion (RC) Curves, Balanced Noise Criterion (NCB) Curves, Noise Rating (NR) Curves, Audiometric Room Curves (per ANSI S3.1, per OSHA Hearing Conservation Amendment, and per ISO Hearing Screen for Audiology Booths)

OPTIONAL SPEECH INTELLIGIBILITY FUNCTION
 

Firmware can be installed in the SoundPro¢â series to allow the testing and evaluation of intelligibility of human speech through public address (PA), fire alarm and mass notification systems (MNS) the STI-PA method in accordance with IEC 60268-16 and NFPA 72 National Fire Alarm Code. Results are in STI or CIS. On meter post-processing available

OPTIONAL REVERBERATION TIME (RT-60)

Used to measure decay time or acoustic decay performance of a room or closed space Specifications for the SoundPro

PORTS AND CONNECTIONS :

 

POWER JACK

External power supply 9-16 VDC

AC/DC OUTPUT

3.5 mm stereo (tip-AC, Ring-DC, Ring2-Ground)

10 PIN AUXILIARY CONNECTOR

RS-232, 3 digital outputs, 1 digital input

USB

Conforms to USB 2.0, mini-USB connector

ELECTRICAL CHARACTERISTICS :

 

BATTERIES
 

4 disposable AA alkaline cells, typically >10 hours continuous use without backlight (SLM only without filters activa ted);
optional nickel metal hydride (NiMH) cells, typically 10+ hours (SLM only)

EXTERNAL DC POWER INPUT

100 – 240 VAC, 47-63 Hz transformed to 9 VDC

STANDARD MICROPHONES

Class/Type 1 Precision – BK4936; Class/T ype 2 General Purpose – QE7052; other optional types and sizes available from ¼" to 1" prepolarized or standard condenser types

MICROPHONE POLARIZATION

Selectable 0 volts or 200 volts (Class/Type 1 models only)

MICROPHONE SENSITIVITY

Selectable nominal values in decibels relevant to 1 Volt/Pa

METER INPUT

50 KOhm nominal input impedance

PREAMPLIFIER

Removable preamp directly accepts ½" (0.52" or 13.2 mm) microphone; other sizes require adapter

REMOTE CABLE

Will drive up to 15 meters of cable with negligible signal loss

INPUT IMPEDANCE

20 k  in series with 11 µF capacitance, with 100 pF capacitance to ground

PHYSICAL CHARACTERISTICS :

 

SIZE

3.1"W X 11.1"H X 1.6" thick (with preamp & microphone); 7.9 cm X 28.2 cm X 4.1 cm

WEIGHT

0.54 kg or 1.2 lbs. (including batteries)

TRIPOD MOUNT

Standard photographic mount on rear accepts ¼"- 20 screw threads

HOUSING

Stainless fiber filled ABS polycarbonate with additional internal EM/RFI shielding

ENVIRONMENTAL :

 

TEMPERATURE

Operating -10º C to +50º C (<± 0.5 dB effect); Stora ge -25º C to +70º C

HUMIDITY

10% to 90% RH, non-condensing

EXTERNAL FIELDS

Electric – 10 V/meter, 1 kHz modulated, 30 MHz – 1 GHz, <55 dBC; magnetic - 80 A/m, 50/60 Hz, no significant effect

 