±â°èÁøµ¿ÃøÁ¤±â (°¡¼Óµµ, ¼Óµµ, º¯À§ÃøÁ¤) Model/VM-4515SI
»ç¾ç / Á¦Ç°¹øÈ£
Frequency Range
5Hz~10Hz
Measuring Range Acceleration(ACC) Velocity(VEL) Displacement(DISP) Temperature
5~10Hz 1,3,10,30,100,300§¾, 6-ranges10~1kHz 10,30,100,300,1000§®/s, 5-ranges10~150Hz 0.1,0.3,1,3,10mmp-p, 5-ranges0~150¡É
Indication
EOP, RMS value(ACC,VEL), EQP(DISP)
Accuracy Frequency Response Sensitivity Error Sensitivity Switching Error Meter Linearity
Within ±5% (20Hz~500Hz) (at 80Hz typical)Within ±5% (at 80Hz FS)Within ±2%|Within ±1.5% of F.S.
Output Waveform Output Level Output Temperature Level Output
AC OUT 0 ~ ±1V (with a load?10k¥Ø)DC OUT 0 ~ +1V (with a load?10k¥Ø)DC OUT 0 ~ +1V (with a load?10k¥Ø)
Power Supply Battery External battery AC Power supply
6F22 : 1pce, Life time:20hrs approx. at continuous use9~18V, 20mA max.100V AC (with optional AC adapter)
Calibaration Output
80Hz sinusoidal waveLevel is adjustable using variable resistor in battery box
Dimensions & Weight
Main unit : 80W×166H×86Dmm, 320gPickup : Ø14×28.5mm, 32gProbe : Ø6×55mm, 16g
°æ±âµµ Àǿսà À̷̹Π40 (Æ÷Àϵ¿ 653) Àδö¿ø¾ÆÀÌƼ¹ë¸® Aµ¿ 10Ãþ 1021È£(¿ìÆí¹øÈ£ 16006)
Tel) 031-8084-3340 / Fax)031-8084-3344 / E-mail)kineqt@kineqt.com
Ä«µå°áÁ¦°¡´É