»ç¾ç / Á¦Ç°¹øÈ£
|
NoiseProTM
|
Measurement Range:
|
40 to 110 dB RMS, 70 to 140 dB RMS, 115 to 143 dB Peak
|
Dynamic Range:
|
70 dB RMS, 28 dB Peak
|
Amplitude Resolution:
|
0.1 dB
|
Dose Resolution:
|
0.001% to 9999%, auto-scaling always shows 4 digits
|
Statistical Distribution Resolution:
|
0.1 dB increments for fast & slow
|
Number of Channels:
|
(1) RMS, (1) Peak
|
Frequency Weighting per Channel:
|
RMS: A or C, Peak: A, C or Z
|
Time Constant per Dosimeter:
|
Slow or Fast may be selected for each dosimeter. If impulse is chosen it will be applied to all.
|
Exchange Rate per Dosimeter:
|
3, 4, 5 or 6 dB
|
Criterion Level per Dosimeter:
|
40 to 140 dB in 1 dB increments
|
Criterion Time per Dosimeter:
|
1 to 24 hours in 1 hour increments
|
Personal Noise Exposure Level Times per Dosimeter:
|
1 to 18 hours in 1 hour increments
|
Threshold Level per Dosimeter:
|
Off or any threshold from 40 to 140 dB in 1 dB increments
|
Upper Limit Value per Dosimeter:
|
40 to 140 dB in 1 dB increments
|
Ceiling Limit Value per Unit:
|
(1) FastMax and (1) SlowMax, 40 to 140 dB
|
Data Labels per Unit:
|
ISO/IEC or basic (U.S.) nomenclature
|
# of Setup Files in Memory:
|
(5) Factory-de ned and (4) User-de ned
|
Date & Time:
|
DD/MM/YYYY; HH:MM:SS AM/PM or 24-hour clock
|
Data Available Via Display:
|
Setup lename, Pre-calibration date & time, Post-calibration date & time, SPL, Lavg/Leq, Peak, Slow Min, SlowMax, FastMin, FastMax, TWA, Projected TWA, Dose, Projected dose, SEL, Exposure, Run time
|
Keypad Combination Lock:
|
(2) User-de ned 4-digit codes, (1) for run/stop access, (1) for setup access
|
Display:
|
Backlit 128 x 64 pixel graphical LCD
|
Languages:
|
English, Spanish, German, French, Portuguese, and Italian
|
Reports:
|
Via QuestSuite Professional II or RS-232C transmission of ¡°Smart Report¡± to HyperTerminal
|
Size:
|
2.7¡± x 5¡± x 1.5¡± (68.6mm x 127mm x 38.1mm)
|
Weight:
|
14 ozs., (369g.)
|
Power:
|
Typically (70) hrs from (2) AA disposable alkaline batteries
|
Mechanical:
|
Industrial-grade cast aluminum, IP-65 rated case. Removable belt clip with tripod mounting adapter
|
Operating Temperature Range:
|
-10¢ª to +50¢ª C, +14¢ª to +122¢ª F
|
Storage Temperature Range:
|
-25¢ª to +60¢ª C, -13¢ª to +140¢ª F
|
Humidity Range:
|
0 to 95% non-condensing
|
Intrinsic Safety Certi cations:
|
UL, cUL, MSHA, Ex, ATEX
|
Product Standards:
|
CE Mark, EN 61252, ANSI S1.25
|
Software Compatibility:
|
QuestSuite Professional II and HyperTerminal
|
Optional Features:
|
Vibrating alarm belt clip and boom microphone
|