www.kineqt.com

ÀÛ¾÷ȯ°æÃøÁ¤Àåºñ

  µµ½Ã¸ÞŸ(ÀÛ¾÷ȯ°æ¼ÒÀ½ÃøÁ¤±â)

  Air Sampling Pump
  (°³Àν÷áäÃë¿ë ÆßÇÁ)

  WBGTÃøÁ¤±â

  Anemometer(Á¤¾ÐÇü¿­¼±Ç³¼Ó°è)

  ±âŸ ÀÛ¾÷ȯ°æÃøÁ¤Àåºñ

     PGM-1100

     DX-200

     M-1/2/4

     NI-100

     RS-60

     3MTM E-A-RFit
        Validation System

¼ÒÀ½ÃøÁ¤Àåºñ

Áøµ¿ÃøÁ¤Àåºñ

´ë±âÃøÁ¤Àåºñ

¼öÁúÃøÁ¤Àåºñ

 

 

 ÀÛ¾÷ȯ°æÃøÁ¤Àåºñ > ±âŸ ÀÛ¾÷ȯ°æÃøÁ¤Àåºñ > ÀÛ¾÷ȯ°æ¼ÒÀ½Àü±¤ÆÇ(±âÁØ·¹º§ÃÊ°ú½Ã ºÎÀú±â´É) RS-60


 ÀÛ¾÷ȯ°æ¼ÒÀ½Àü±¤ÆÇ(±âÁØ·¹º§ÃÊ°ú½Ã ºÎÀú±â´É)  Model/RS-60

 

                          ÀÛ¾÷ȯ°æ¼ÒÀ½Àü±¤ÆÇ(±âÁØ·¹º§ÃÊ°ú½Ã ºÎÀú±â´É) RS-60      


  Á¦Ç°Æ¯Â¡

- DL-100 -
¡Ü
»ýÈ°¹æ¼ö°¡ °¡´ÉÇϹǷΠ¾î´À Àå¼Ò³ª ¼³Ä¡°¡ °¡´ÉÇÏ´Ù.
¡Ü °íÈÖµµÀ̹ǷΠÇöÀç ¼ÒÀ½µµ¸¦ ¾î´À Àå¼Ò¿¡¼­³ª °üÂûÇÒ ¼ö ÀÖ´Ù.
¡Ü »ï°¢´ë, µÞ(¹è°æ)ÆÇ³Ú µî ¾îµð¿¡µç ¼³Ä¡°¡ °¡´ÉÇÏ´Ù.

- RS-60 -
¡Ü ÇöÀå¿¡¼­ ÇöÀåÀ¸·Î À̵¿¼³Ä¡°¡ °¡´ÉÇϹǷΠ¿À·£±â°£ »ç¿ëÀÌ °¡´ÉÇÏ¿© ¸Å¿ì °æÁ¦ÀûÀ̶óÇÒ ¼ö ÀÖ´Ù.
¡Ü Leq(µî°¡¼ÒÀ½), Max(ÃÖ´ë°ª)À»10°³¿ù ÀÌ»ó ÀúÀå °¡´ÉÇÏ´Ù.
¡Ü ÀúÀåµÈ Data´Â Software¸¦ ÀÌ¿ë·°ü¸®ÇÒ ¼ö ÀÖ´Ù.
¡Ü Software´Â ÀåºñÀÇ Á¤»óÀÛµ¿À¯¹«, ¹åµ¥¸®¹æÀüÀ¯¹«, Àü¿ø°ø±ÞÀ¯¹«¿¡ µû¸¥ ¿À·ù¸¦ È®ÀÎÇÒ ¼ö ÀÖÀ¸¸ç, ÃøÁ¤ Data¸¦ ½Ã°£´ëº°·Î °ü¸®    ÇÒ ¼ö ÀÖ´Ù.
¡Ü »ýÈ° ¹æ¼ö°¡ °¡´ÉÇϹǷΠ¾î´À Àå¼Ò³ª ¼³Ä¡°¡ °¡´ÉÇÏ´Ù.
¡Ü ¿¬ÀåÄÉÀ̺í(10, 20, 30, 60m µî)À» »ç¿ëÇÏ¿© ÃøÁ¤¼¾¼­¿Í °Å¸® ¿¬ÀåÀÌ °¡´ÉÇÏ´Ù.
¡Ü °¢ ÇöÀå¿¡ ¸Â´Â ±ÔÁ¦dB°ªÀ» ÀÚÀ¯·ÎÀÌ ¼³Á¤ÇÏ¿© °æ±¤µî ¹× ºÎÀúÀÛµ¿ ½Ã½ºÅÛÀ» ±¸ÃàÇÒ¼öÀÖ´Ù.(¼±ÅÃÇ°¸ñ)


  Á¦Ç°±¸¼ºµµ

   

< ´ëÇü¼ÒÀ½Ç¥½Ã±â, ÆdzÚ,°æ±¤µî >

< ÇöÀå¿ÜºÎ ¹× ³»ºÎ¼ÒÀ½ µ¿½Ã Ç¥½Ã ¼³Ä¡»ç·Ê >

- Á¦Ç° ±¸¼º -

 

< ±âº»±¸¼ºÇ°¸ñ >
- °íÁ¤½Ä¼ÒÀ½ÃøÁ¤±â(RS-60)
- ´ëÇü¼ÒÀ½Ç¥½Ã±â(DL-100)
- ÃøÁ¤¼¾¼­(LMX-8)
- µ¥ÀÌŸ°ü¸®¼ÒÇÁÆ®¿þ¾î(SFTR60)
- ¼¾¼­°íÁ¤¿ë¾ÆÅ©¸±¹Ú½º
- ¼ÒÀ½ÃøÁ¤±â ¹æ¼öÄÉÀ̽º

< ¼±ÅÃÇ°¸ñ >
- ´ëÇü¼ÒÀ½Ç¥½Ã±â µÞ(¹è°æ)ÆdzÚ
- ¼ÒÇü °³ÀΠŹ»ó¿ë ¼ÒÀ½Ç¥½Ã±â
- °æ±¤µî ¹× ºÎÀú ÀÛµ¿ ½Ã½ºÅÛ

     

< ÃøÁ¤¼¾¼­&¼¾¼­°íÁ¤ÄÉÀ̽º >

< °íÁ¤½Ä¼ÒÀ½ÃøÁ¤±â&¹æ¼öÄÉÀ̽º >

< Data °ü¸® Software >


  ÇöÀ弳ġ»çÁø

   

< »ï¼º°Ç¼³ >

< Çö´ë°Ç¼³ >

   

< GS°Ç¼³ >

< ´ë¸²°Ç¼³ >

   

< ¼­¿ï½Ãû >

< Á¾·Î±¸Ã» Áýȸ¼ÒÀ½ >

   

< ¼­¿ï´ëº´¿ø Á¶¸®½Ç >

< Data °ü¸® Software >


  Á¦Ç°»ç¾ç

»ç¾ç / Á¦Ç°¹øÈ£

RS-60

Frequency range

20 ~ 20000Hz

Frequency Weightings

A-Weighting, C-Weighting

Time Weightings

Fast, Slow

Measurement range

5 range (30~90, 40~100, 50~110. 60~120, 70~130)

Functions

LeqT, LFmax, LSmax etc.

Memory

60 days minute-by minute (all parameters are stored)

Main Power &
Battery Power

Main Power(220V, 50~60Hz), Battery Power Supply : with automatic recharge Minimum duration : 5days

Outputs

• RS-232 Serial                   • Parallel Printer
• Remote display(DL-100) and relay box(REL-2)

Accessories included

• ¹æ¼öÄÉÀ̽º× 1                  • ¸¶ÀÌÅ©·ÎÆù¿¬ÀåÄÉÀ̺í30m × 1
• ¸¶ÀÌÅ©·ÎÆùº¸È£ÄÉÀ̽º× 1   • Data °ü¸®S/W ×1
• ´ëÇü¼ÒÀ½Ç¥½Ã±â(DL-100) × 1

 

°æ±âµµ Àǿսà À̷̹Π40 (Æ÷Àϵ¿ 653) Àδö¿ø¾ÆÀÌƼ¹ë¸® Aµ¿ 10Ãþ 1021È£(¿ìÆí¹øÈ£ 16006)

Tel) 031-8084-3340 / Fax)031-8084-3344 / E-mail)kineqt@kineqt.com

Ä«µå°áÁ¦°¡´É