¼ÒÀ½ÃøÁ¤Àåºñ > ±â°è ¹× ¼³ºñÁø´Ü ¼ÒÀ½ÃøÁ¤±â > VM-0110
|
´Ù-ä³Î ¼ÒÀ½/Áøµ¿ºÐ¼®±â, 1/1~1/24¿ÁŸºê ¹× FFT (Model/VM-0110)
|
|
¡á ±âº» 6ä³Î¿¡¼ ÃÖ´ë 7 2ä³Î±îÁö È®Àå°¡´É
¡á ¿Âµµ¼¾¼, ¾Ð·Â¼¾¼, ½Àµµ¼¾¼, Áøµ¿°¡¼Óµµ°èµî ´Ù¾çÇÑ ¼¾¼¿Í ¿¬°á°¡´É
¡á ½ºÆåÆ®·³, ÆÄÇüºÐ¼®, 1/1~1/12¿ÁŸºêºÐ¼®µî ´Ù¾ç ÇÑ µ¥ÀÌÅÍ ºÐ¼®±â´É °¡´É
¡á ÄÄÇ»ÅÍ·ÎÀÇ ºü¸¥ µ¥ÀÌŸ Àü¼Û
¡á °¡¼Óµµ°è, ¼º¸Çü°¡¼Óµµ°è, Àü¾ÐÃâ·Â¼¾¼µî°ú »ç¿ë°¡´É
|
|
|
|
|
|
|
|
|
VM-0110 SOFTWARE |
|
Unit
|
Functions
|
Content
|
Description
|
Logger [DS-0110R]
|
Logging Channel No.
|
Max. 72 channel
|
-
|
Logging Operation
|
One-shot. Continuous
|
-
|
Trigger Function
|
Level, external signal, Timer
|
Single operation, repeat operation, Post trigger can be set
|
Display Function
|
Waveform, Compressed waveform, rms
|
Converts to physical unit
|
Memory Function
|
voice memo, text memo
|
Sound function for PC is necessary for voice memo
|
Logging Time
|
Depends on HDD space
|
6ch, 1kS/s, 10MB consumes at 10min.
|
Remote Control Function
|
Control of VM-0110 unit
|
Logging channel, sampling rate, Amp (×1.10.100) range
|
Analysis [DS-0110A]
|
Time-series Waveform display
|
Any zoom, auto-scale
|
Select 1ch/6ch
|
Time-series Waveform Edition
|
Search function
|
Peak value, threshold
|
Calculation between cursor
|
Max. value, min value, average value, rms, amplitube(p-p), time difference
|
Differential. integral
|
1-time differential, 2-time differential, 1-time integral, 2-time integral
|
DC process
|
Delete extract
|
Calculation among channel
|
£«£×÷
|
Uint conversion function
|
Default unit is setting unit at logging
|
Any filter function
|
High-pass, Low-pass, band-pass and band stop
|
Envelope Zoom
|
- -
|
Frequency Axis Display
|
Windows function
|
Hanning+haming. Rectangular. Flat Top, Blackman etc
|
Cursor function
|
Frequency difference, Level Difference
|
Zoom function
|
|
Frequency Analysis
|
Spectrum
|
Amplitube, power
|
Mutual spectrum
|
Cross-specturm, transfer characteristic Coherence
|
Octave band analysis
|
Band width(1/1, 1/3, 1/6, 1/12) Logarithmic average process
|
Voice Memo Recall
|
Voice file recall
|
Display of memo mark, reproduction of voice memo(needs wave file reproduction software)
|
File Output
|
Time-series waveform data, analysis data
|
CSV file, F2 format file (for vibration test type)
|
Printing
|
Time-series waveform graph, analysis graph
|
Screen printing
|
Other
|
Temperate save
|
Save of environmental setting
|
-
|
|
|
VM-0110 HARDWARE
|
|
Unit
|
Functions
|
Content
|
Description
|
Basic Unit (VM-0110)
|
See below.
|
See below.
|
See below.
|
Measuring Unit
|
Measuring Channel No.
|
6 Channel
|
Analogue input module ×2 loading
|
Variable Digital Filter
|
6 th butterworth LPF
|
Set cut-off frequency from software
|
Variable Gain Amplifier
|
×1, ×10, ×100
|
Set by software (each channel individual)
|
Sampling Rate
|
Max. 102.4kHz/ch
|
(at 12 channel logging)
|
A/D Resolution
|
16 bit
|
|
Monitor signal output
|
Analogue voltage signal
|
1-channel selection by rotary switch
|
Analogue signal output
|
Analogue voltage signal
|
Sinusoidal waveform(10~2kHz), M-series random waveform
|
Base Unit
|
Host Interface
|
IEEE 1394
|
Communication with host PC
|
Digital I/O
|
Input ×2 , Output ×2
|
Input (external trigger, synchronous signal),Output (synchronous signal)
|
Card Slot
|
PCMCIA ×1, Card bus slot ×1
|
Memory card for data recording Wireless card load(planing)
|
Power Supply
|
24VDC
|
|
Power Consumption
|
60W
|
At VD-0110×5, TYPE 1×12 loading)
|
Operation Environment
|
0 ~ + 5 0¡É
|
|
Outer Dimensions
|
268W×210H×246D mm
|
At VD-0110×5loading)without protrusion
|
Weight
|
6.6kg approx.
|
At VD-0110×5 loading)
|
|
|
Unit
|
Functions
|
Content
|
Description
|
Measuring Unit(VM-0110)
|
See Measuring Unit
|
See Measuring Unit
|
Analogue signal output is nil due to expansion unit.
|
Analogue Input Module
|
See below.
|
See below
|
See below.
|
VA-0110C
|
Pickup connect×3
|
Accelerometer
|
Frequency : 3~60kHz Max.Input : ±15,000pC/±150,000pC
|
VA-0110S
|
Pickup connect×3
|
Servo or Piezo type acceleration pickup
|
Frequency : DC/0.1~500kHz Max.Input : ±1 0 V
|
VA-0110X
|
General signal inputX3
|
Voltage current Constant current drive PU.
|
Frequency : 3~60kHz Max.Input : ±10V, 0~20mA, Drive current 3.5mA
|
Connection cable
|
Synchronous measurement signal I/O
|
Connection of basic unit
|
Synchronous measurement over 37ch
|
Battery
|
Battery drive
|
Output 24V, 7.5Ah
|
Continuous drive over4hrs (At TYPE 1×12, 36ch measurement)
|
Card type Memory
|
Data save
|
PCMCIA, Card-bus
|
Save in this unit only
|
On-line Setting Software [DS-0110HD]
|
On-line measurement
|
Logging condition setting by only this unit
|
-
|
Host PC
|
Note PC
|
|
Check necessary software install and operation
|
Communication Card
|
Windows 2000 IEEE 1394 I/F card
|
IEEE 1394 communication cable is necessary
|
|
|
|